Robust and reliableDesigned for industrial use, environmental monitoring, laboratory analysis, and online applications, it offers the highest level of robustness in its electronic, hydraulic, and mechanical components. With complete separation between the electronic and a simple, robust hydraulic section, it allows for reliable and long-term use.
Easy to installThe analyser is supplied ready for use, following a series of analytical tests performed at the end of its production cycle, along with a set of parts for its field start-up.
Automatic calibrationThe analyser performs pre-settable automatic calibration cycles by the user; the new calibration factor is verified and accepted if it falls within the predefined limits.
Measurement frequency: User-selectable; between two measurements, the analyser remains in standby mode, without consuming any reagents.
Selection of measurement rangesThe analyser operates in an extended measurement field; depending on the sample concentration, the measurement ranges are automatically selected.
Re-analysis of out-of-scale readings: The analyser identifies samples that are out of range and re-analyses the sample after automatic dilution.
Optional sampler: The analyser can optionally be fitted with a portable sampler, which allows for the automatic measurement of up to 8 pre-collected samples.
| MEASUREMENT PRINCIPLE | Dual-beam colorimetric, ISE (ion-selective electrode), NDIR, UV |
| Measurement type | Batch - Multiparallel version: batch, sequential and multi-wavelength |
| MEASUREMENT FREQUENCY | Programmable |
| Measurement time | From 5 minutes to 60 minutes depending on the application |
| MEASUREMENT POINTS | Up to 4 per single method |
| Operator Interface | 8” colour graphic touch screen (optional) |
| OUTPUT SIGNAL AND COMMUNICATION PORTS | Separate 4–20 mA outputs for each method or flow, galvanically isolated; RS232 output; optional RS485; optional RTU or Modbus TCP |
| Entrance Signals | Analysis: 1 digital contact with photocoupler, galvanically isolated Calibration: 1 digital contact with photocoupler, galvanically isolated |
| ALARM CONTACTS | Auxiliary relay: 1 zero-potential SPDT contact, max load 110 V
AC/DC 1 A General fault: 1 SPDT contact, zero potential, max load 110 V AC/DC 1 A Standby/Occupato: 1 x SPDT zero-potential contact, max load 110 V AC/DC 1 A |
| ALARM MESSAGES | On the operator interface |
| SAMPLE FEED | Atmospheric pressure Temperature: 10° - 35 °C Volume: 50/80 mL per analysis depending on the analyser model |
| REAGENT REPLACEMENT | 3 to 5 weeks depending on the frequency of measurement |
| Room temperature | 10-45°C (Reagents up to 25°C) |
| ASSEMBLY | Countertop |
| STANDARD PROTECTION | IP 55, superior class upon request |
| HARDWARE | PC104 standard microcontroller, integrated 8" colour touchscreen |
| Feeding | 115/230 V AC 50/60 Hz – IEC socket with external power supply Button – 12/24 V DC on request |
| ABSORPTION | 15 W on standby, 40 W during analysis |
| WEIGHT | 14 kg excluding reagents and the reagent compartment |
| DIMENSIONS | 430 × 260 × 540 mm (H × W × D) excluding the reagent compartment |
Select a parameter to download the relevant technical data sheet
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Connect with our experts to find the perfect solution for your needs
your company. Schedule a demo or request a quote today.