EASYCHEM TOX Early Warning is a discrete analyser equipped with a colour touchscreen monitor housed in an industrial cabinet, comprising a refrigerated compartment for bacteria, reagents, calibrators and control solutions. A rotating mechanical arm performs aspiration, transfer and dispensing of solutions into 80 cuvettes located in a rotating, thermostatted reaction plate, including a luminometric reading system and integrated with an automatic cuvette washing station.
To allow extended use of rehydrated bacterial cultures for up to 10 days, proprietary marine bacteria have been selected, grown, stabilised, and freeze-dried in ready-to-use vials, in accordance with ISO 11348-3. This method ensures that, after automatic rehydration, the microorganisms retain a measurable bioluminescence signal and unchanged sensitivity to various reference substances, such as zinc sulphate and mercury chloride, in accordance with the aforementioned ISO or GB-T standard. The system is programmed to manage numerous bacterial vials sequentially in a fully automated manner, enabling a high frequency of automatic analysis over an extended period (approximately one month of autonomy for unattended operation).
| Technology | Online real-time toxicity trend - DAMTA* Analytical monitoring and toxicity assessment device |
| DETECTOR AND READING | High-sensitivity light meter - Direct reading |
| Microspecimen reaction cuvettes | 80, reusable after washing and quality control; 6.0 mm |
| REACTION PLATE TEMPERATURE | Adjustable from 15 to 25 °C, accuracy: ±0.1 °C |
| LEVEL SENSORS | Samples/Reagents/Waste |
| SAMPLE REQUIREMENTS | 100-200 m³/h at ambient pressure |
| SAMPLE/AMBIENT TEMPERATURE | Sample: 5 to 35 °C; Ambient: 5 to 28 °C; Relative humidity at 28 °C <40% |
| Feeding | 110/230 V AC, 50/60 Hz |
| Energy consumption | 400 W |
| DIMENSIONS/WEIGHT | 160 (W) x 80 (D) x 50 (H) cm / 100 kg without reagents |
| PC and Software | PC panel with integrated touchscreen, dedicated software |
| Ethernet port Data transmission via FTP GPRS DATA TRANSMISSION ANALOGUE OUTPUT DIGITAL OUTPUT - ALARM |
Standard Standard via Ethernet port or with optional 3G modem With optional 3G modem 4-20 mA - optional Optional |
| REAGENTS | Lyophilised bacterial vials: rehydration and direct use Analysis swabs and positive controls: ready for use |
| Refrigerated reagent tray | Programmable positive reference check |
| Calibration Interval | Reference control - programmable |
| REPLACEMENT OF REAGENTS | 30 days with maximum frequency; with lower frequencies, reagent replacement up to 3 months |
| SAMPLING | Continuous data in the sampling container, 2-minute moving average |
| Measurement frequency | Programmable; maximum frequency: 2.5 minutes |
| EVENT RESPONSE TIME | Minimum 60 seconds - Maximum 150 seconds |
| Analysis time until final result | From 1 to 15/30 minutes, depending on sample toxicity |
| Real-time calculation | Real-time calculation of all parameters required by standards UNI EN ISO 11348-3 and GB-T 15441 | EMPTY FIELDS (Checking for false negatives and false positives) | Programmable for one vacuum per sample | SAMPLE REPLICA AND POSITIVE CONTROL (Validation of false positives) | Programmable after any report of toxicity The analyser performs a new test on the sample with a maximum of 5 dilutions, one positive control and calculates the EC50 in case of toxicity above a predefined threshold. |
Select a parameter to download the relevant technical data sheet
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Connect with our experts to find the perfect solution for your needs
your company. Schedule a demo or request a quote today.