Robust and reliable Designed for applications in industrial environments, it guarantees maximum electronic, mechanical and hydraulic reliability. Complete separation between electronics and hydraulics, along with the extreme simplicity and robustness of the LFA hydraulic circuit, ensure safe and reliable long-term operation.
Easy to install: The analyser is shipped, after a series of rigorous tests, ready for installation with a starter set of reagents; simply connect the sample, drain and power to begin analysis.
Automatic calibration At times set by the operator, the analyser performs automatic calibration, emitting an alarm signal in the event of an anomaly in the calibrant's optical density.
Dialysis of the sample: The sample can be dialysed beforehand to eliminate matrix effects and/or to dilute it. Dialysis allows for the analysis of wastewater samples without any interference.
Analysis frequency: programmable by the operator, within the time interval between two analyses the analyser enters standby mode without consuming reagents.
Reanalysis of outliers: the analyser recognises out-of-range values and re-analyzes them “in dilution”.
| MEASUREMENT PRINCIPLE | Dual-beam colorimetric, ISE (ion-selective electrode), NDIR, UV |
| Type of measurement | Batch - Multiparallel version: batch, sequential and multi-wavelength |
| MEASUREMENT FREQUENCY | Programmable |
| MEASURING TIME | From 5 minutes to 60 minutes depending on the application |
| MEASUREMENT POINTS | Up to 4 per single method |
| Operator Interface | 8” colour graphic touch screen (optional) |
| OUTPUT SIGNAL AND COMMUNICATION PORTS | 4-20 mA separate for each method or flow, galvanically isolated; RS232 output; optional RS485; optional RTU or Modbus TCP |
| Entrance Signals | Analysis: 1 digital contact with photocoupler, galvanically isolated Calibration: 1 digital contact with photocoupler, galvanically isolated |
| ALARM CONTACTS | Auxiliary relay: 1 zero-potential SPDT contact, max load 110 V
AC/DC 1 A General fault: 1 SPDT contact, zero potential, max load 110 V AC/DC 1 A Standby/Occupato: 1 x SPDT zero-potential contact, max load 110 V AC/DC 1 A |
| ALARM MESSAGES | On the operator interface |
| SAMPLE FEED | Atmospheric pressure Temperature: 10° - 35 °C Volume: 50/80 mL per analysis depending on the analyser model |
| REAGENT REPLACEMENT | 3 to 5 weeks depending on the frequency of measurement |
| Room temperature | 10-45°C (Reagents up to 25°C) |
| ASSEMBLY | Countertop |
| STANDARD PROTECTION | IP 55, superior class upon request |
| HARDWARE | PC104 standard microcontroller, integrated 8" colour touchscreen |
| Feeding | 115/230 V AC 50/60 Hz – IEC socket with external power supply Button – 12/24 V DC on request |
| ABSORPTION | 15 W on standby, 40 W during analysis |
| WEIGHT | 14 kg excluding reagents and the reagent compartment |
| DIMENSIONS | 430 × 260 × 540 mm (H × W × D) excluding the reagent compartment |
Select a parameter to download the relevant technical data sheet