Easychem Eco

Easychem ECO is a laboratory routine analyser for measuring pH, conductivity and turbidity in liquid samples.

This fully automated instrument is based on discreet technology and is equipped with a 104-position sampler including standards and controls; the main features are as follows:

  • sample temperature measurement for pH and conductivity;
  • Combined glass pH electrode, mounted in a low-volume flow cell for stable and reliable pH measurements;
  • low-flow cell for rapid conductivity measurements;
  • Low flow cell for nephelometric turbidity measurements

Productivity: 60 tests/hour (20 samples, 3 parameters each).

The Easychem ECO analyser is controlled by our SW Fusion, installed on a PC running the Windows® operating system, where the operator creates the work list containing the samples, their origin, the associated code and the required determinations for each sample to be analysed. There, they can control the automatic analysis in real-time and finally verify and print the results.

Advantages and benefits

  • Ease of use: no specific experience required, only brief training is needed.
  • Low operating costs: consumption limited to sample tubes.
  • Quick start: simply define the job list and run the analysis on all the predefined methods in the software.
  • One-button shutdown: software-controlled shutdown.
  • Software for Windows: easy to use and to learn through a short training course, specifically designed for chemists.
  • QC checks: up to 10 levels of real-time QC checks can be defined; the results are automatically stored and plotted in a specific section.
  • QC actions: if QC results fall outside the tolerance limits, the analysis may be halted, or the operator will simply find a record of the malfunction in the QC alarm messages.

Parameters analysed

SKU PWR-MICC-18 Categories , Tags , ,

Technical Specifications

Technology Continuous flow system with a peristaltic pump, easily accessible
CHAMPION CAPACITIES 104 positions for samples, standards and controls
MEASUREMENT PRINCIPLE pH: combined pH electrode in a continuous-flow cell, temperature-controlled sample, pH values corrected for temperature
Conductivity: continuous flow conductivity meter with cell constant correction, temperature compensation
Turbidity: nephelometric measurement at 850 nm, to determine the concentration of suspended particles in a water sample by measuring the incident light scattered at a right angle from the sample
STANDARD RANGE pH: 0–14, standard calibration at 4–7–10
Conductivity: up to 4910 µS/cm
Turbidity: 0–20 NTU
SAMPLE RANGE 60 tests per hour (20 samples, 3 parameters each)
SAMPLING Via a 4-position peristaltic pump, with long-life silicone tubing
CALIBRATORS AND QUALITY CONTROL On the sample tray
SAMPLE TEMPERATURE COMPENSATION Yes, standard, pH and conductivity
DETECTORS pH: glass electrode, range 0–14, temperature range 0–80 °C, junction type: nylon. Electrode slopes calculated during automatic calibration.
Conductivity: flow-through conductivity meter, cell constant calculated during automatic calibration.
Turbidity: incident-light nephelometric flow cell at 805 nm, measured at 90°, correlated with turbidity via automatic calibration.
Communication software Compatible with Windows XP, 7.0 and 8.0; automatic data transfer to a PC; multiple data analyses
Sample Analysis Job lists stored by the software with pre-selected profiles and the option to select a separate set of parameters for each sample
CHAMPION ID Alphanumeric
RANDOM ACCESS TO SAMPLES, CALIBRATIONS, ETC. Yes
ADDING SAMPLES DURING RUNNING Yes
Automated calibration Yes, independent calibrators for each method, pH 3 calibrators, Conductivity up to 10 calibrators, Turbidity up to 10 calibrators
CALIBRATION ADJUSTMENTS pH: slopes 4–7 and 7–10; Conductivity and Turbidity: linear, polynomial or as a function of a factor
MULTI-LEVEL QUALITY CONTROL AND CLOSED-LOOP SYSTEM Up to 10 quality control levels, with closed-loop control (quality control and pre-programmed actions in case of quality control error)
QUALITY CONTROL DATA BANK AND CONTROL CHART Yes
Calibration correction YES; enabling/disabling calibrators modifies the calibration fit
IMPORTING THE WORK LIST AND EXPORTING THE RESULTS TO LIMS Yes
Room temperature 15°C–45°C
ASSEMBLY Counter-top, indoor
Feeding 15V DC - 70W; external power supply with 110/220 switch
In 230V AC to 15V DC supply including n. 2 fuses: 2T 2A at 230V AC (internal), 2A at 230V AC (external)
Energy consumption less than 70 VA (external PC included)
Earth Resistance under 0.1 Ohm
Leakage current less than 2.5 mA
Dimension and weight 40x60x45 cm (AxPxL); Weight 15 kg

Documentation

Brochure

Complete installation guide

Select a parameter to download the relevant technical data sheet

FAQs

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Related Products and Models

Micromac 2000 - fully automated analyser

Micromac 2000

EASYCHEM TOX Early Warning - Robotic Technology Direct Reading Analyser

Easychem TOX Early Warning

Easychem Coli Online

Easychem Coli Online

EASYCHEM TOX Early Warning - Robotic Technology Direct Reading Analyser

Easychem Online

Request information

Connect with our experts to find the perfect solution for your needs
your company. Schedule a demo or request a quote today.