EasyChem Plus is a discrete analyser Composed of:
| Technology | Continuous flow, via an easily accessible peristaltic pump |
| SAMPLE / REAGENT PREHEATING | Yes |
| CHAMPION CAPACITIES | 60 positions for samples, white, standard and controls |
| TEST TIMES | Up to 200, single reagent / 120-150, double reagent |
| TEST TIMES | 100, single reagent / 50, double reagent |
| DOSING SYRINGE (SAMPLE AND REAGENTS) | 1000-microlitre syringe with a resolution of 0.3 µL; automatic zeroing; accuracy of ±0.5% from 5 to 1000 microlitres; externally mounted syringe for easy maintenance |
| number of reagent positions | 18 x 35 mL, diluents included |
| Reagent tray stock solutions | Yes, working calibrators and quality control diluted from stock |
| DILUENT POSITION | On your refrigerated reagent tray |
| Refrigerated reagent tray | Yes, standard |
| Reagent level sensor | Yes |
| NUMBER OF REACTION PITS | 96 reaction microcuvettes with programmable incubation temperature +/- 0.1 °C |
| Optical Path Length (mm) | 10 mm or 50 mm |
| REACTION PLATE TEMPERATURE | Adjustable from 37°C to 50°C, +/- 0.2°C |
| Incubator type | Thermoelectric |
| Flow cell type | Optical glass |
| Main detector | Colorimetric, temperature-controlled; halogen lamp with extended UV emission; automatic zeroing; accuracy of +/- 1% from 0 to 2.5 O.D.; linearity better than 0.5%; noise +/- 2 m Abs. at 340 nm 2.5 O.D. |
| Detector Technology | Interference filters |
| Number of wavelengths | 9 + white |
| READING METHODS | Endpoint: mono- or bichromatic; differential endpoint; sample blank correction; kinetic |
| CADMIUM REDUCTION MODULE FOR NO3 | Yes, via CD column – automatic regeneration |
| Communication software | Compatible with Windows XP, 7.0, 8.0 and 10 |
| SAMPLE ANALYSIS | Saved job lists from the software with the ability to select an independent list of parameters for each sample |
| CHAMPION ID | Alphanumeric |
| Random access to samples, calibrations, etc. | Yes |
| SAMPLE ADDED DURING EXECUTION | Yes |
| RESET OF SAMPLES AND REAGENTS | Yes |
| WORKING CALIBRATION DILUTION | Yes, from stock solution placed in the chilled tray |
| Pre-run sample dilution | Yes |
| POST-RUN DILUTION OF THE SAMPLE | Yes, auto-dilution and re-injection of out-of-scale samples |
| MULTILEVEL QUALITY CONTROL AND CLOSED LOOP | Up to 5 levels of control, with closed loop and pre-programmed actions in case of quality control and/or spike recovery error |
| DATABASE AND QUALITY CONTROL CHART | Yes |
| AUTOMATIC SPIKE CONTROL AND RECOVERY | Yes |
| AUTOMATIC CALIBRATIONS; LINEAR, POLYNOMIAL, ETC. CALIBRATION CURVES. | Yes; up to 16 calibrators |
| Calibration correction | Yes; it allows you to enable/disable calibrants and modify the calibration fit |
| QUALITY CONTROL CALIBRATION AND RECALIBRATION | Yes, if the correlation is below the set value for re-calibration |
| REAGENT WHITE OPTICAL DENSITY (OD) CONTROL AND UPPER CALIBRATION | Yes, with pre-programmed actions in case of out-of-tolerance conditions |
| CORRECTION OF RESULTS | Yes, correction by dilution factor, humidity and weight |
| Importing Work List and Exporting Results to LIMS | Yes |
| MULTIPLE DILUENTS (SOILS, PHENOL ANALYSIS, CYANIDES ETC.) | Yes |
| DIMENSIONS / WEIGHT | 35 cm x 67 cm x 70 cm (H x W x D) / 45 kg |
| Feeding | 240 VAC or 110 VAC - 50/60 Hz; single phase with earth; fuses 3.15 Amp 230 VAC, 6.3 Amp 115 VAC |
Select a parameter to download the relevant technical data sheet
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Connect with our experts to find the perfect solution for your needs
your company. Schedule a demo or request a quote today.