| Technology | Direct reading |
| SAMPLE / REAGENT PREHEATING | Yes |
| SAMPLE CAPACITY AND NUMBER OF REAGENTS | a) Samples: 10 positions dedicated to samples / Reagents: 20 positions x 40 mL each, including stocks and diluents b) Samples: 20 positions for samples / Reagents: 10 positions x 40 mL each, including stock and diluents |
| TEST TIMES | Up to 200, single reagent / 120-150, double reagent |
| TEST TIMES | Up to 150, single reagent |
| DOSING SYRINGE (SAMPLE AND REAGENTS) | 368-microlitre syringe with a resolution of 0.07 µL; automatic zeroing; accuracy of ±0.5% from 2 to 350 µL |
| Reagent tray stock solutions | Yes, working calibrators and quality control diluted from stock |
| DILUENT POSITION | On your refrigerated reagent tray |
| Refrigerated reagent tray | Yes, standard |
| REAGENT AND SAMPLE LEVEL SENSOR | Yes |
| NUMBER OF REACTION CUVETTES | 96 single-use reaction microcuvettes; incubation temperature programmable +/- 0.1 °C |
| Optical Path Length (mm) | 10.0 mm |
| REACTION PLATE TEMPERATURE | Adjustable from 37 °C to 50 °C, +/- 0.1 °C |
| Incubator type | Thermoelectric |
| Cuvette cell type | BioNex® disposable |
| Main detector | Colorimetric, temperature-controlled; halogen lamp with extended UV emission; automatic zeroing; accuracy of +/- 1% from 0 to 2.5 O.D.; linearity better than 0.5%; noise +/- 2 m Abs. at 340 nm 2.5 O.D. |
| DETECTOR TECHNOLOGY / NUMBER OF WAVELENGTHS | Interference filters / 9 + white |
| READING METHODS | Endpoint: mono- or bichromatic; differential endpoint; sample blank correction; kinetic |
| COMMUNICATION AND SOFTWARE | USB port; software compatible with Windows XP, 7.0, 8.0 and 10 |
| SAMPLE ANALYSIS | Saved job lists from the software with the ability to select an independent list of parameters for each sample |
| CHAMPION ID | Alphanumeric |
| Random access to samples, calibrations, etc. | Yes |
| SAMPLE ADDED DURING EXECUTION | Yes |
| RESET OF SAMPLES AND REAGENTS | Yes |
| WORKING CALIBRATION DILUTION | Yes, from stock solution placed in the chilled tray |
| Pre-run sample dilution | Yes |
| POST-RUN DILUTION OF THE SAMPLE | Yes, auto-dilution and re-injection of out-of-scale samples |
| MULTILEVEL QUALITY CONTROL AND CLOSED LOOP | Up to 5 quality control levels, with closed-loop control and pre-programmed actions in case of quality control and/or spike recovery error |
| DATABASE AND QUALITY CONTROL CHART | Yes |
| AUTOMATIC SPIKE CONTROL AND RECOVERY | Yes |
| AUTOMATIC CALIBRATIONS; LINEAR, POLYNOMIAL, ETC. CALIBRATION CURVES. | Yes; up to 16 calibrators |
| Calibration correction | Yes; it allows you to enable/disable calibrants and modify the calibration fit |
| QUALITY CONTROL CALIBRATION AND RECALIBRATION | Yes, if the correlation is below the set value for re-calibration |
| REAGENT WHITE OPTICAL DENSITY (OD) CONTROL AND UPPER CALIBRATION | Yes, with pre-programmed actions in case of out-of-tolerance conditions |
| CORRECTION OF RESULTS | Yes, correction by dilution factor, humidity and weight |
| Importing Work List and Exporting Results to LIMS | Yes |
| POSSIBILITY OF USING MULTIPLE DILUENTS (SOILS, PHENOLS ANALYSIS, CYANIDES ETC.) | Yes |
| DIMENSIONS / WEIGHT | 40 cm x 60 cm x 38 cm (height x width x depth) / 20 kg 15.7 in x 23.6 in x 14.9 in / 41.8 lb |
| Feeding | 110-240 VAC - 50/60 Hz; single phase with earth; 2.0 Amp 230 VAC fuses, 4.0 Amp 115 VAC fuses |
Select a parameter to download the relevant technical data sheet
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Connect with our experts to find the perfect solution for your needs
your company. Schedule a demo or request a quote today.