Easychem Plus

A new generation of routine laboratory analyzers

NEW! Available for SEA WATER analysis


The EasyChem Plus discrete analyzer meets the demands of the changing marketplace, without compromising performance. EasyChem Plus is a flexible instrument able to perform several different tests all on the same sample, without operator intervention.

EasyChem Plus requires no specific experience to operate, and can be learned by anyone in a matter of minutes. Operation consists of simply loading the sample tray, selecting the tests to be performed, and “clicking” start. It’s that simple! Labor costs are greatly reduced and productivity increased, by enabling the technician to perform other tasks.

EasyChem Plus does all the work. No longer is there any variation in results based on who the operator is, or what kind of day they may be having. EasyChem Plus performs up to 120 tests per hour of true unattended operation, with the highest possible data quality, regardless who “clicks” start.

EasyChem’s sleek design, ease of use, user friendly software, and price, makes it attractive to most laboratories that perform automated or manual wet chemistry.

EasyChem Plus Discrete Analyzer, including:

  • 60 sample tray capability including blanks, standards and controls;
  • Up to 18 reagents in a temperature controlled tray;
  • 96 reaction cuvettes temperature controlled;
  • Colorimeter with a computer controlled filter wheel, for automatic wavelength selection;
  • Standard flow cell 10 mm, 20 mm or 50 mm pathlength (sea water version);
  • Auto Pre run sample dilution;
  • Auto sample dilution for off scale samples;
  • On line QC and QC database including QC chart;
  • Throughput: 60 test for hour;
  • Cd coil reduction option for Nitrate.

Features and benefits

  • Easy to use; no specific experience or attitude is required;
  • Run flexibility; individual parameters list can be selected for each samples;
  • Low reagent consumption; only a few microliters of reagent for sample;
  • Low running costs; nearly no consumables, low reagent and disposable costs;
  • No hydraulics problems; computer batch controlled analyzer, no reagents or sample continuously pumped in a manifold, no breaks of air or gas bubbles, noise etc.;
  • Software EASY to use and to learn; short training, no waste of time to create specific hydraulics background.

Data Handling System

The Optical Density (O.D.) is processed by the EasyChem Plus Windows software on an external PC. The final results are printed in a report containing all relevant information including: sample ID, sample O.D., date, QC values and parameters analyzed. Real time results and O.D. values are visible during the run.

 

 

 



Wednesday, 07 April 2010 08:27

Micromac Total N&P

On line analyzer for nitrogen and phosphorus
monitoring in surface and waste water
 

Micromac C TN&TP is designed to analyze Total Nitrogen and Total Phosphorus in the same device; UV digestion is applied for Total N, UV and high temperature digestion for Total P.

The measurement is performed in a combined mode, ensuring one hour of measurement for both parameters; 4-20 mA  data output is provided at the same time.

Measurement method 

The sample after proper filtration is pumped inside the LFA
reactor, where after injection of H2SO4 is trapped inside the
high temp heating bath for inorganic P hydrolysis. During
the hydrolysis time, the analyzer runs a complete TN test on
the same sample, by adding the oxidation reagents and
passing through a UV digestion step, to convert Nitrogen
into Nitrate by UV radiation in persulfate alkaline medium.
The nitrates formed are then reduced to nitrites by hydrazine
in alkaline solution, where copper is used as catalyst; the
nitrites react with sulphanilamide and
naphtylethylendiamine in acid solution, to form a pink
colored compound measurable at 550 nm.
The reactor is washed and then the analyzer opens the
heating bath and adds in the digested sample a proper
oxidant to convert all the organic forms of phosphorus into
orthophoshate, by the double action of potassium
persulphate and UV radiation in acid environment. The
orthophosphate formed reacts with molybdate to form
phosphomolybdate, which is finally reduced to blue
molybdenum by ascorbic acid. The coloured complex is
read at 660 or 880 nm.
The sample after proper filtration is pumped inside the LFA reactor, where after injection of H2SO4 is trapped inside the high temperature heating bath for inorganic P hydrolysis. During the hydrolysis time, the analyzer runs a complete TN test on the same sample, by adding the oxidation reagents and passing through a UV digestion step, to convert Nitrogen into Nitrate by UV radiation in persulfate alkaline medium. The nitrates formed are then reduced to nitrites by hydrazinein alkaline solution, where copper is used as catalyst; the nitrites react with sulphanilamide and naphtylethylendiamine in acid solution, to form a pink colored compound measurable at 550 nm. The reactor is washed and then the analyzer opens the heating bath and adds in the digested sample a proper oxidant to convert all the organic forms of phosphorus into orthophoshate, by the double action of potassium persulphate and UV radiation in acid environment. The orthophosphate formed reacts with molybdate to form phosphomolybdate, which is finally reduced to bluemolybdenum by ascorbic acid. The coloured complex is read at 660 or 880 nm.
 

Technical specification

  Total N Total P
Measuring principle Colorimetric, UV digestion + UV reduction to NO3 Colorimetric, acidic hydrolosis and UV digestion
Measuring range 0-5/10/20/50 mg/l as N  0-3/5/10 mg/l as P

 

Features and benefits

  • TN&TP measured in the same device
  • One hour analysis time for both parameters
  • Fully automatic operation
  • Long autonomy; low maintenance and operating cost
  • Low reagents consumption
  • Easy operation; plug in analyzer, no special training is required
  • Electronics and hydraulics separated
  • Serial interface for local or remote PC connection

The results of the analysis are displayed in the same moment, after 1 hour.

Published in On-line analyzers