  On-line analyzers for COD monitoring
in water and wastewater

 

Three versions of COD on-line analyzers are available:

  • dichromate method
  • permanganate index method
  • UV direct reading method.

The dichromate method follows the international standard where in the sample, after filtration, Potassium Dichromate, Mercury (II) sulfate and Sulfuric acid with a proper catalyst are added; Mercury (II) sulfate concentration is adjusted to mask the expected Chloride amount.

The sample is then heated at 170° for 20 minutes or at 150° up to 2 hours (digestion time and digestion temperature can be adjusted depending on the matrix to digest completely all the substances that give a contribute to COD). After digestion the sample is cooled and the absorbance measured at 592 nm is proportional to a COD concentration.

The permanganate index is defined as the quantity of oxygen, expressed as mg/l, equivalent to the consumed permanganate when a water sample is treated with as solution of potassium permanganate in acid environment and at a temperature of 100°C for 10 minutes. The sample is mixed with diluted sulphuric acid, it is then heated at about 100°C, when the first addition of KMnO4 is performed: this first addition may be followed by others, depending on the measuring range. The digestion time in the standard configuration is set to 10 minutes but it can be selected depending on the matrix.

After digestion the sample is cooled and the decrease of the absorbance measured at 525 nm corresponds to the permanganate consumed by the organic substance.

The UV direct reading method is a more simple method where the COD is correlated to the direct light absorption of the water sample measured at 254 nm.

 

<<Pause>>
  1. 23-05-2013:

    AMS-SYSTEA launches the new Easychem TOX on-line !

    ET On-Line



    We are pleased to announce the launch in the international market of the new Easychem TOX on-line, the innovative direct read analyzer for the combined measurement of acute toxicity and chemical parameters in water.

    This is the first analyzer featuring the measurement of acute toxicity and chemical measurements in the same device, with possibility to integrate other instruments and sensors and sending data to Internet: a complete early warning water quality monitoring station in a single rack! 

    DOWNLOAD FLYER



    read more >>>
  2. 27-11-2012:

    AMS-SYSTEA announces the new Easychem TOX discrete routine laboratory analyzer !

    EasyChemTox_001_red



    We are pleased to announce the new Easychem TOX, the state-of-the-art direct read discrete laboratory analyzer for automated determination of acute toxicity in water samples based on bioluminescent bacteria.

    This innovative analyzer completely automates the manual proedures usually applied to perform the evaluation of toxicity according to ISO 11348-3 procedure, ensuring up to 45 samples/hour throughput.

    DOWNLOAD BROCHURE



    read more >>>
  3. 19-12-2011:

    AMS group and SYSTEA s.p.a. have merged,
    giving rise to AMS-SYSTEA

    AMS group and SYSTEA s.p.a. announce their global partnership finalized to merge, giving rise to AMS-SYSTEA.

    Logo_ams_systea


    AMS Group and SYSTEA s.p.a., specialists in the field of design, manufacture and sales of analysis equipment, have announced their next merger and the creation of AMS-SYSTEA. This new company will result from the strategic merge of sales and R&D operations implemented in August 2011.

    The goal of both businesses is to pool valuable skills, expertise and facilities within a common structure, thereby providing one of the most comprehensive product offerings in the sector.

    Download here the official announcement



    read more >>>
  4. 21-06-2011:

    SYSTEA announces the new Micromac C Arsenic (low level) for drinking water on-line analysis!

     

    Micromac_C_new

    After several months of hard development, we are pleased to announce the new Micromac C Arsenic, featuring a low detection limit down to 1 microgram/litre for on-line analysis of drinking water samples.

    Recently the worldwide water regulations lowered the threshold limits for Arsenic in drinking water down to 10 micrograms/litre, due to scientifically demonstrated cancerogenity of this dangerous chemical analyte.

    Micromac C Arsenic allows now to achieve feasible on-line low concentration measurements for drinking water applications. 

    DOWNLOAD BROCHURE    



    read more >>>

Who's online

We have 16 guests online

Search